Section 12213A Operators
1
1
1
" 1
1
GENERAL INFORMATION
INTRODUCTION
The TEKTRONIX 2213A Oscilloscope is a rugged, light
weight, dual-channel 60 MHz instrument that features a
bright, sharply defined trace on an 80- by 100 mm cathode-
ray tube (crt). Its vertical system supplies calibrated deflec
tion factors from 2 mV per division to 5 V per division.
Trigger circuits enable stable triggering over the full band
width of the vertical system. The horizontal system provides
calibrated sweep speeds from 0.5 s per division to 50 ns per
division, along with a delayed-sweep feature. A X I0 magni
fier circuit extends the maximum sweep speed to 5 ns per
division when the SEC/DIV switch is set to 0.05 fis per
division.
The instrument is shipped with the following standard
accessories:
1 Operators manual 2 Probe packages
1 Power cord
For part numbers and information about instrument ac
cessories, refer to the Options and Accessories section of
this manual.
The service manual and all other optional accessories are
orderable from Tektronix, Inc. A local Tektronix Field Office,
representative, or the Tektronix product catalog can provide
ordering and product information.
SPECIFICATION
The following electrical characteristics (Table 1-1) are
valid for the 2213A when it has been adjusted at an ambient
temperature between +20°C and +30°C, has had a warm
up period of at least 20 minutes, and is operating at an
ambient temperature between 0°C and +50°C (unless oth
erwise noted).
Items listed in the Performance Requirements” column
are verifiable qualitative or quantitative limits, while items
listed in the Supplemental Information” column are either
explanatory notes, calibration setup descriptions, perfor
mance characteristics for which no absolute limits are speci
fied, or characteristics that are impractical to check.
Environmental characteristics are given in Table 1-2. The
2213A meets the requirements of MIL-T-28800C, para
graphs 4.5.5.1.3, 4.5.5.1.4, and 4.5.5.1.2.2 for type III,
Class 5 equipment, except where otherwise noted.
Physical characteristics of the instrument are listed in
Table 1-3.
REV DEC
1983
1-1

Table of Contents

Other manuals for Tektronix 2213A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2213A and is the answer not in the manual?

Tektronix 2213A Specifications

General IconGeneral
BrandTektronix
Model2213A
CategoryTest Equipment
LanguageEnglish

Related product manuals