I.
I_'.·
l.-;·
Operating
lnformation-465
20 MHz BW/TRIG
VIEW
INVERT
VERT
MODE
DC: All
components
of
the
input
signal are passed
to
the
Vertical
Amplifier.
Dual-purpose switch
that,
when
pulled
out,
limits
the
bandwidth
of
the
complete
Vertical Deflection
System
to
approximately
20
MHz,
or
when
pressed causes signal pre-
sent
in
A Trigger
Generator
circuit
to
be displayed
on
the
CRT.
Pushbutton
switch
that
inverts
the
Channel 2 display.
Selects
the
vertical
mode
of
opera-
tion.
CH
1: Displays Channel 1
only.
ALT:
Dual-trace display
of
signals
on
both
channels.
Display
is
switched
between
channels
at
the
end
of
each sweep.
ADD:
Signals applied
to
the
CH
1
OR X
and
CH
2 OR Y
connect-
ors are algebraically
added
and
the
sum
is
displayed
on
the
CRT.
The
INVERT
switch
in
Channel 2 allows
the
display
to
be
CH
1 +
CH
2
or
CH
1 -
CH
2.
CHOP: Dual-trace display
of
signals
on
both
channels.
Display
is
switched
between channels
at
an
approximate
repetition
rate
of
250
kHz.
CH
2 OR
X-Y:
Displays Channel 2
only.
Must be
pushed
when
op-
erating
in
X-Y
mode.
A
and
B Triggering {both where applicable)
COUPLING
2-4
Determines
the
method
used
to
couple
signal
to
input
of
trigger
circuits.
AC:
Rejects DC
and
attenuates
signals
below
about
60
Hz. Ac-
cepts
signals above
about
60
Hz.
LF
REJ:
Rejects DC
and
attenuates
signals below
about
50
kHz. Ac-
cepts
signals
above
about
50
kHz.
SOURCE
SLOPE
LEVEL
HF R EJ: Accepts signals between
60
Hz
and
50
kHz. Rejects
DC
•-·•
and
attenuates
all signals outside
..,
the
above range.
DC:
Accepts
all
trigger signals from
DC
to
100 MHz or greater.
Selects
source
of
trigger signal.
NORM: Internal trigger signal ob-
tained
from
Vertical Deflection
System.
Actual
source
is
signal(s) displayed on CRT.
CH
1: A
sample
of
the
signal
connected
to
the
CH
1 OR X
input
connector
is
used
as
a
trigger signal.
CH
2: A
sample
of
the
signal
connected
to
the
CH
2 OR Y
input
connector
is
used
as
a
trigger signal.
EXT: Trigger signal
is
obtained
from
signal
connected
to
the
External
Trigger
Input
con-
nector.
EXT
--:--10
(A trigger
circuit
only):
External
trigger signal
is
attenu-
ated
by
a
factor
of
10.
STARTS
AFTER
DELAY
(B
trig-
ger
circuit
only):
B sweep starts
immediately
after
the
delay time
selected
by
the
DELAY-TIME
POSITION dial
and
the
DELAY-
TIME
switch.
LINE (A trigger
circuit
only):
Trigger signal
is
obtained
from a
sample
of
the
line voltage
applied
to
the
instrument.
Selects
the
slope
of
the
trigger
signal which
starts
the
sweep.
+:
Sweep
can
be triggered from
the
positive-going
portion
of
the
trigger signal.
-:
Sweep
can be triggered from
the
negative-going
portion
of
the
trigger signal.
Selects
the
amplitude
point
on
the
trigger signal
at
which
the
sweep
is
triggered.
®

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 465 and is the answer not in the manual?

Tektronix 465 Specifications

General IconGeneral
BrandTektronix
Model465
CategoryTest Equipment
LanguageEnglish

Related product manuals