2260B Series User Manual
106
0 = Disable
1 = Return to factory settings
0, 1 = 2260B version
2, 3 = 2260B build year
4, 5 = 2260B build month/day
6, 7 = Keyboard CPLD version
8, 9 = Analog-Control CPLD version
A, B = Reserved
C, D = Kernel build year
E, F = Kernel build month/day
Power On Configuration Settings*
0 = Panel control (local)
1 = External voltage control
2 = External resistance control (Ext-
R 10kΩ = Vo, max)
3 = External resistance control (Ext-
R 10kΩ = 0)
0 = Panel control (local)
1 = External voltage control
2 = External resistance control (Ext-
R 10kΩ = Io,max)
3 = External resistance control
(Ext-R 10kΩ = 0)
0 = OFF at startup
1 = ON at startup
T001 ~ T010 = Run Test Sequence
TXX at start up
0 = Master/Local
1 = Master/Parallel1
2 = Master/Parallel2
3 = Slave/Parallel
4 = Slave/Series (Only 30V, 80V
models)