EasyManuals Logo
Home>Tektronix>Power Supply>Keithley 2260B Series

Tektronix Keithley 2260B Series User Manual

Tektronix Keithley 2260B Series
207 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #177 background imageLoading...
Page #177 background image
APPENDIX
173
APPENDIX
2260B Default Settings
The following default settings are the factory configuration settings
for the power supply (Function settings/Test settings).
For details on how to return to the factory default settings, see page
56.
Initial Settings
Default Setting
Output
Off
LOCK
0 (Disabled)
Voltage
0V
Current
0A
OVP
Maximum
OCP
Maximum
Normal Function
Settings
Setting
Default Setting
Output ON delay time
F-01
0.00s
Output OFF delay time
F-02
0.00s
V-I mode slew rate select
F-03
0 = CV high speed priority
Rising voltage slew rate
F-04
60.00V/s (2260B-30-XX)
160.0V/s (2260B-80-XX)
500.0V/s (2260B-250-XX)
1600V/s (2260B-800-XX)
Falling voltage slew rate
F-05
60.00V/s (2260B-30-XX)
160.0V/s (2260B-80-XX)
500.0V/s (2260B-250-XX)
1600V/s (2260B-800-XX)

Table of Contents

Other manuals for Tektronix Keithley 2260B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix Keithley 2260B Series and is the answer not in the manual?

Tektronix Keithley 2260B Series Specifications

General IconGeneral
BrandTektronix
ModelKeithley 2260B Series
CategoryPower Supply
LanguageEnglish

Related product manuals