Rising current slew rate
F-06
72.00A/s (2260B-30-36)
144.0A/s (2260B-30-72)
216.0A/s (2260B-30-108)
27.00A/s (2260B-80-13)
54.00A/s (2260B-80-27)
81.00A/s (2260B-80-40)
9.000A/s (2260B-250-4)
18.00A/s (2260B-250-9)
27.00A/s (2260B-250-13)
2.880A/s (2260B-800-1)
5.760A/s (2260B-800-2)
8.640A/s (2260B-800-4)
Falling current slew rate
F-07
72.00A/s (2260B-30-36)
144.0A/s (2260B-30-72)
216.0A/s (2260B-30-108)
27.00A/s (2260B-80-13)
54.00A/s (2260B-80-27)
81.00A/s (2260B-80-40)
9.000A/s (2260B-250-4)
18.00A/s (2260B-250-9)
27.00A/s (2260B-250-13)
2.880A/s (2260B-800-1)
5.760A/s (2260B-800-2)
8.640A/s (2260B-800-4)
Internal resistance
setting
F-08
0.000
Bleeder circuit control
F-09
1 = ON
Buzzer ON/OFF control
F-10
1 = ON
Measurement Average
Setting
F-17
0 = Low
Lock Mode
F-19
0 = Panel lock: allow output off
USB/GPIB setting
Rear Panel USB Mode
F-22
2 = USB CDC, Auto Detect Speed
GPIB address
F-23
8
LAN setting
LAN
F-36
1 = Enable
DHCP
F-37
1 = Enable
Sockets active
F-57
1 = Enable
Web Server active
F-59
1 = Enable
Web password active
F-60
1 = Enable

Table of Contents

Other manuals for Tektronix Keithley 2260B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix Keithley 2260B Series and is the answer not in the manual?

Tektronix Keithley 2260B Series Specifications

General IconGeneral
BrandTektronix
ModelKeithley 2260B Series
CategoryPower Supply
LanguageEnglish

Related product manuals