Measure
3-46
TDS3000B Serie s User Manual
Measurement name Definition
Positive
Duty
Cycle
Measurement of the first cycle in the waveform.
Positive Duty Cycle =
Positive Width
Period
× 100%
Positive
Overshoot
Measured over the entire waveform.
Positive Overshoot =
Max–High
Amplitude
× 100%
Positive
Width
Measurement of the first positive pulse in the
waveform. The time between the 50% amplitude
points.
Rise Time Time that the leading edge of the first pulse in the
waveform takes to rise from 10% to 90% of its
amplitude.
RMS The true Root Mean Square voltage over the entire
waveform.
Snapshot All
Measurements
Displays all measurement values (except two-chan-
nel measurements) at the time you pushed the
Snapshot All Measurements button, for the
selected waveform. Push the Snapshot A ll
Measurements button to update the list values.
Push the MENU OFF button to clear the list from
the screen.

Table of Contents

Other manuals for Tektronix TDS3000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS3000B Series and is the answer not in the manual?

Tektronix TDS3000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS3000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals