Command Handler Supported Commands
Table G-1. DLP NIRscan Nano Supported Commands (continued)
COMMUNICATIONS INTERFACE
USB BLUETOOTH
READ /
DESCRIPTION
WRITE
OPCODE
CHARACTERISTI
SERVICE NAME SERVICE UUID
C UUID
BYTE 1 BYTE 2
0x43484103-444C-
5020-4E49-
GATT General 0x53455201-444C-
52204E616E6F,
READ Scan status 0x02 0x19 Information Service 5020-4E49-
0x43484104-444C-
Table I-3 52204E616E6F
5020-4E49-
52204E616E6F
WRITE Reset Tiva 0x02 0x1A
WRITE Write ADC PGA gain 0x02 0x1B
FACTORY USE ONLY: Write
WRITE 0x02 0x1C
DLPC150 Register
(1)
READ Read DLPC150 register 0x02 0x1D
WRITE Generate patterns 0x02 0x1E
Save given scan configuration
WRITE 0x02 0x1F
in EEPROM
0x43484114-444C-
5020-4E49-
52204E616E6F,
GATT Scan
0x53455205-444C- 0x43484115-444C-
Read stored scan Configuration
READ 0x02 0x20 5020-4E49- 5020-4E49-
configurations Information Service
52204E616E6F 52204E616E6F,
Table I-6
0x43484116-444C-
5020-4E49-
52204E616E6F
Erase all stored scan
WRITE 0x02 0x21
configurations
0x43484113-444C-
Read number of stored scan
READ 0x02 0x22 5020-4E49-
configurations
52204E616E6F
GATT Scan
0x53455205-444C- 0x43484117-444C-
Configuration
READ Read active scan configuration 0x02 0x23 5020-4E49- 5020-4E49-
Information Service
52204E616E6F 52204E616E6F
Table I-6
0x43484118-444C-
WRITE Set active scan configuration 0x02 0x24 5020-4E49-
52204E616E6F
WRITE DLPC150 power control 0x02 0x25
WRITE Set scan subimage 0x02 0x26
FACTORY USE ONLY: Erase
Calibration Coefficients,
Reference Calibration
WRITE 0x02 0x27
Coefficients, and Scan
Configuration stored in
EEPROM
(2)
READ Read PGA setting 0x02 0x28
FACTORY USE ONLY: Write
WRITE spectrum calibration 0x02 0x29
coefficients
(2)
(2)
Commands highlighted in red are for factory calibration. Erasing the factory calibration data will render a unit non-functional and
will need to be recalibrated.
59
DLPU030BJune 2015Revised July 2015 DLP NIRscan Nano Command Description
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments DLP NIRscan and is the answer not in the manual?

Texas Instruments DLP NIRscan Specifications

General IconGeneral
BrandTexas Instruments
ModelDLP NIRscan
CategoryMotherboard
LanguageEnglish

Related product manuals