2007.03.07Flow2 stairliftTab 06: Systematic fault finding
www.ThyssenKruppAccessibility.nl28
Error messages
Error code E54
Type of error User error / system error
Error message Right-handed squeeze condition
Description The lift has been stopped by an obstacle on the right side of the chair.
Priority Low
Possible
solution
- If possible, allow the lift to move to the left and remove the obstacle.
If error code E54 appears, switch the lift to mode 3 and use the [I] and [D]
buttons to 'release' the lift from the squeeze condition.
- If the error occurs without there being a squeeze condition, check the
squeeze opto and the connection cable.
Replace defective parts.
Reset Stop the lift
Modes 0, 2
Error code E55
Type of error System error
Error message Command error
Description Incorrect command received from a control.
Priority Low
Possible
solution
- Remove the joystick from the control concerned and place it back again.
- Switch the control off and on again by briefly disconnecting the batteries.
- Switch the stairlift off and check the ribbon cable and the connectors
between the main board and the receiver module. Then switch the stairlift
back on again.
Reset Switch off and on.
Modes 0, 2

Other manuals for ThyssenKrupp Flow2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ThyssenKrupp Flow2 and is the answer not in the manual?

ThyssenKrupp Flow2 Specifications

General IconGeneral
BrandThyssenKrupp
ModelFlow2
CategoryStairlifts
LanguageEnglish

Related product manuals