2007.03.07Flow2 stairliftTab 06: Systematic fault finding
www.ThyssenKruppAccessibility.nl32
Error messages
4.3 Overview of possible error codes
Possible
solution
- Check the brake/drive motor and replace if necessary.
Reset Switch off and on.
Modes 0, 2
Code Comment Reset Priority Mode
E01 Software inconsistency error Switch off Highest 0, 1, 2, 3, 6
E02 Service unit circuit error Switch off Highest 0, 2
E03 Read parameter error Switch off Highest 0, 2
E04 Table-data corrupted Switch off Highest 0, 2
E05 Safety MCU not responding Switch off Average 0, 2
E06 Safety MCU programming failure Switch off Highest All modes
E07 Safety MCU read failure Switch off High 0, 2
E10 Relay circuit error Switch off Average 0, 1, 2, 3, 4, 5, 6
E11 Brake circuit error Switch off Average 0, 1, 2, 3, 6
E20 Invalid main drive position Switch off High 0, 1, 2
E21 Invalid swivel position Switch off High 0, 1, 2
E30 Swivel-zero opto circuit error Switch off High 0, 2
E31 Squeeze opto circuit error Switch off High 0, 2
E32 Osg opto circuit error Switch off High 0, 2
E33 Tornswitch opto circuit error Switch off High 0, 1, 2
E40 Drive motor board h-bridge malfunction Switch off High All
E41 Level motor board H-bridge malfunction Switch off High All
E42 Swivel motor board H-bridge
malfunction
Switch off High All
E50 Low battery Switch off High 0, 1, 2, 3, 4, 5, 6
E51 Osg tripped Switch off Average 0, 2
E52 Levelling error Switch off Average 0, 1, 2