EasyManuals Logo
Home>ThyssenKrupp>Stairlifts>Flow2

ThyssenKrupp Flow2 User Manual

ThyssenKrupp Flow2
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
2007.03.07 Flow2 stairlift Tab 06: Systematic fault finding
www.ThyssenKruppAccessibility.nl 29
Error messages
Error code E56
Type of error System error
Error message Pre-levelling error
Description Horizontal motor not powerful enough to set the chair straight.
Priority Low
Possible
solution
- Switch the stairlift off and on.
- Sit straight up in the chair (stepping off is even better) and try to move the
lift again. The chair must now be horizontal and the lift must move again.
It is possible that an E52 error occurs during this movement. This is
normal. Switch the stairlift off and on again. The E52 error may not occur
again.
- If the stairlift remains still, there is something wrong with the horizontal
system. Work through the possible solutions of E52.
Reset Switch off and on.
Modes 0, 2
Error code E60
Type of error Mechanical fault
Error message Drive motor overload
Description The drive motor has been overloaded for a preset time (standard = 2 seconds).
Priority High
Possible
solution
- Switch the lift off and on.
- Check the connections on the motor module.
- Check the mechanical part of the drive mechanism.
- Check whether replacing the motor module solves the problem.
- Check the brake connection.
Reset Switch off and on.
Modes 0, 1, 2, 3, 4, 6

Other manuals for ThyssenKrupp Flow2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ThyssenKrupp Flow2 and is the answer not in the manual?

ThyssenKrupp Flow2 Specifications

General IconGeneral
BrandThyssenKrupp
ModelFlow2
CategoryStairlifts
LanguageEnglish

Related product manuals