EasyManuals Logo
Home>ThyssenKrupp>Stairlifts>Flow2

ThyssenKrupp Flow2 User Manual

ThyssenKrupp Flow2
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
2007.03.07Flow2 stairliftTab 06: Systematic fault finding
www.ThyssenKruppAccessibility.nl30
Error messages
Error code E61
Type of error Mechanical fault
Error message Level motor overload
Description The level motor has been overloaded for a preset time (standard = 2 seconds).
Priority High
Possible
solution
- Switch the lift off and on.
- Check the connections on the motor module.
- Check the mechanical part of the level mechanism.
- Check whether replacing the motor module solves the problem.
Reset Switch off and on.
Modes 0, 1, 2, 3, 4, 5, 6
Error code E62
Type of error Mechanical fault
Error message Swivel motor overload
Description The swivel motor has been overloaded for a preset time (standard = 2 seconds).
Priority High
Possible
solution
- Switch the lift off and on.
- Check the connections on the MCM.
- Check the mechanical part of the swivel mechanism.
- Check whether replacing the motor module solves the problem.
Reset Switch off and on.
Modes 0, 1, 2, 3, 4, 5, 6
Error code E70
Type of error System error / control error
Error message Swivelling outside limits

Other manuals for ThyssenKrupp Flow2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ThyssenKrupp Flow2 and is the answer not in the manual?

ThyssenKrupp Flow2 Specifications

General IconGeneral
BrandThyssenKrupp
ModelFlow2
CategoryStairlifts
LanguageEnglish

Related product manuals