3.3- TECHNICAL DATA
Tab.1 contains the technical data characterising the device.
8
INSTALLATION AND USE INSTRUCTIONS
TF24R/44R
TECHNICAL DESCRIPTION -3
Power supply voltage
Output voltage
Max. output current
Absorbed power
Service According to the motors connected
Double electric insulation yes
Prearrangement connection
to external devices
230 V - 50 Hz
230 V ~
TF24/R TF44/R
1,35 A
62 W
Wind, rain, brightness sensors, AC8
unit control, thermostat and manual control
Operating temperature
Dimensions
Connectable C20 actuators
Connectable ACK4 actuators
Connectable SL60 actuators
Connectable C30 actuators
Connectable C40 actuators
- 5 ºC + 50 ºC
6 (16*)
4 (16*)
4 (16*)
4
1 (4*)
1 (4*)
1
4 (16*)
24 V
1,3 A
300 W
5 (20*)
1 (4*)
Gross weight
1,3 kg
Class II
Connectable C240 actuators
2
Connectable T50 actuators
1
Connectable T80 actuators
1
(*) Indicated in brackets maximum quantity of actuators connectable with dip-switch No.7 in
OFF position (see page 16, point 9). Motors must be equally located on the four feeding
unit inputs
Tab.1
4 (8*)
4 (16*)
4 (8*)
Connectable C25 actuators
1 (4*)
4 (16*)
Connectable C130 actuators
6 (16*)
4
160 x 120 x 75 mm