Preventive Maintenance/Parts Replacement
Preventive Maintenance
Toshiba 1600EP Series of uninterruptible power systems have been designed to provide years of trouble-
free operation requiring a minimum of preventive maintenance.
The best preventive measure that the UPS user can take is to keep the area around the unit, particularly
the air inlet vents, clean and free of moisture and dust accumulations. If the atmosphere of the installation
site is very dusty, use a vacuum cleaner to periodically remove dust accumulations around and from the
unit.
CAUTION
          
routine maintenance or service on this equipment other than those preventive
maintenance details which are described directly above this caution.
Parts Replacement
The following list shows recommended intervals for periodic replacement of certain UPS parts:
Aluminum electrolytic capacitors: Replace once every 5 years.
Fuses: Replace once every 7 years.
Cooling fan: When operated in an ambient temperature of 86 °F (30 °C) to 104 °F (40°
C), replace every 3.5 years. When operated in an ambient temperature of less than 86 °F
(30 °C) , replace every 5 years.
Batteries: In order to maintain system reliability, the UPS batteries should be replaced on a
regular schedule. To ensure reliable operation, all of the batteries should be replaced at the
same time. Use the following chart for replacement:
UPS BATTERY REPLACEMENT
BATT AMB TEMP AVERAGE LIFETIME (% REDUCED)
68 – 77 °F (20 – 25 °C) Approximately 5 yrs. 0%
86 °F (30 °C) Approximately 3.5 yrs. 30%
95 °F (35 °C) Approximately 2.5 yrs. 50%
104 °F (40 °C) Approximately 1.8 yrs. 66%
113 °F (45 °C) Approximately 1.25 yrs. 75%
1.
2.
3.
4.

Table of Contents

Other manuals for Toshiba 1600EP Series

Question and Answer IconNeed help?

Do you have a question about the Toshiba 1600EP Series and is the answer not in the manual?

Toshiba 1600EP Series Specifications

General IconGeneral
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-15°C to 50°C (5°F to 122°F)
Communication InterfaceRS-232
Humidity0% to 95% relative humidity (non-condensing)
Battery TypeValve-Regulated Lead-Acid (VRLA)

Summary

Product Use and Warranty Restrictions

Qualified Personnel Only

Defines requirements for personnel performing installation and maintenance.

Purpose

Toshiba Customer Support Center

Contact information for assistance with application or operational issues.

General Safety Instructions

Symbols

Explains safety alert, prohibited, mandatory, and hazard symbols used in the manual.

Signal Words

IMPORTANT SAFETY INSTRUCTIONS

QUALIFIED PERSONNEL ONLY

Defines qualifications and responsibilities for personnel working with the UPS.

Product Description

Application and Use

Outlines typical applications for the UPS in office environments.

Output Rating

Lists model capacities and their corresponding output ratings.

Power Backup and Conditioning

Details how the UPS provides backup power and protects loads from disturbances.

Inspection/Storage/Disposal

Storage Guidelines

Provides guidelines for storing the UPS to maintain its condition.

Disposal Information

Information on contacting agencies for proper disposal of electrical components and batteries.

Installation Precautions

Conductor Routing and Grounding

Specifies how to route wires and ensure proper grounding for safety and noise reduction.

Operating Precautions

Equipment Warning Labels

UPS Connections

Terminal Block

Illustrates the terminal block and wiring connections for 208/240 volt units.

Communication Interfaces

Remote Contacts

Details the remote contacts interface and DB9 male connector pin assignments.

UPS Stop Signal Operation

RS-232C

RemotEye II Network Card

Describes the optional network card for remote UPS management.

UPS Specifications

UPS Specifications: 3.6-8kVA Models

Environment

Lists environmental operating and storage temperature, humidity, and altitude.

Operation Diagnosis

Details battery check, input OV protection, battery lifetime, etc.

UPS Specifications: 10-22kVA Models

Environment

Lists environmental parameters like operating temperature and humidity.

Operation Diagnosis

Covers battery check, input OV protection, and internal temperature.

Operating the UPS

Battery Backup Time and Discharge Process

Explains battery backup duration and discharge process.

Starting the UPS

Stopping the UPS

Online Mode

Static-Bypass Mode (Stop Operation)

Describes power flow when the UPS is in bypass mode due to overload or fault.

Display and Keys

Front Panel Layout

Shows the components of the UPS front panel, including LCD and keys.

Data Display Screens

System Warning Messages

System Fault Messages

UPS Protection System

System Protection Functions

Details built-in UPS fault protection functions for various conditions.

Preventive Maintenance/Parts Replacement

Parts Replacement

Lists recommended replacement intervals for UPS components like capacitors, fuses, fans, and batteries.

External Layouts/Dimensions/Shipping Weights

Dimensional Data

Provides a table with physical dimensions for different UPS models.

Related product manuals