2460 ADJUSTMENT 1 - 16 September 1997 © TOSHIBA CORP.
1.2.5 Setting mode (08)
In this mode, the various special modes listed in the Setting Code List can be set or changed.
<Procedure>
Set/change
a value
INT
Memorizing
Clear
PWR
START
Code
Code Name Mode Initial Allowance Remarks
value
200 Internal timer setting ALL — 13 digit Ex)
9 7 0 9 0 1 5 1 3 2 7 4 8
Year ↑ Date ↑ Hour ↑Second
Month Day Minute
201 Destination ALL EUR=0 0~3 0: EUR
UC=1 1: UC
Other=3 2: JPN
3: Other
202 External mounted counter selection ALL 0 0~3 0: No external counter is mounted
1: Coin controller
2: Key card
3: Key counter
204 All clear ALL 3 0~10 0: Not functional
1~10: Set number × 15 sec.
205 Automatic power save ALL 0 0~15 0 = Not functional, 1~5 = Setting value x 30 sec.
6 = 3 min, 7 = 4 min, 8 = 5 min, 9 = 7 min,
10 = 10 min, 11 = 15 min, 12 = 20 min,
13 = 30 min, 14 = 45 min, 15 = 60 min
206 Automatic power off ALL EUR=20 0~20 0 = 3 min, 1 = 5 min, 2 = 10 min, 3 = 15 min,
UC=9 4 = 20 min, 5 = 25 min, 6 = 30 min, 7 = 40 min,
8 = 50 min, 9 = 60 min, 10 = 70 min, 11 = 80 min,
12 = 90 min, 13 = 100 min, 14 = 110 min,
15 = 120 min, 16 = 150 min, 17 = 180 min,
18 = 210 min, 19 = 240 min, 20 = Not functional
209 Background job starting time ALL 1 0~10 1~10: Set number × 15 sec.
250 Telephone number ALL 0 14 digit “–” is input by [HELP] or [INFO] key
251 PM counter, setting value ALL 0 0~999999
252 PM counter, current value ALL 0 0~999999
253 Error history indication ALl – – See page 1-3
254 ADU/Copier cassette loading status ALL 0 0~3 0: Automatic
1: Copier upper cassette is loaded
2: ADU is loaded
3:
Neither ADU nor copier upper cassette is loaded
0 8