55 / 73
Copyright © 2019 Toshiba Teli Corporation, All Rights Reserved. http://www.toshiba-teli.co.jp/en/
TriggerControl
TriggerControl features are related to image acquisition using trigger.
This camera series provides two kinds of exposure synchronization.
1. Normal Shutter mode : Free run operation (internal synchronization)
2. Random Trigger Shutter mode : Synchronized with external trigger input
In Random Trigger Shutter mode, two kinds of trigger input are available.
1. Trigger signal via the CameraLink CC1 (HardwareTrigger)
2. Trigger command via software command (SoftwareTrigger)
The following table shows the combination of operation mode of this camera series.
Operation Mode
‘ExposureTime’ register control
Random Trigger Shutter mode
-Fix mode:TriggerSequence0
‘ExposureTime’ register control
-Level mode:TriggerSequence1
Trigger pulse width control
-Fix mode:TriggerSequence0
‘ExposureTime’ register control
* The camera operation not mentioned above is not supported.