EasyManuals Logo

Toshiba RAS-10GAVP-E User Manual

Toshiba RAS-10GAVP-E
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
18
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E
6-2. Outdoor Unit
RAS-10GAVP-E, RAS-13GAVP-E, RAS-16GAVP-E
No.
1
2
3
4
Parts name
Fan motor (for indoor)
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Louver motor
Type
MF-280-30-5R
( )
( )
MP24Z
Specifications
DC280340V, 30W
10k at 25°C
10k at 25°C
Output (Rated) 1W, 16 poles, DC12V
No.
1
2
3
4
5
6
7
8
9
10
Parts name
Reactor
Outside fan motor
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
Heat exchanger temp. sensor (TE sensor)
Terminal block (6P)
Compressor
Coil for P.M.V.
Coil for 4-way valve
Model name
CH-57
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA111A1F-20F1
CAM-MD12TF
VHV
Rating
L = 10mH, 16A × 2
DC140V, 43W
10k (25°C)
62k (20°C)
10k (25°C)
10k (25°C)
20A, AC250V
3-phases 4-poles 750W
DC12V
AC220240V

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba RAS-10GAVP-E and is the answer not in the manual?

Toshiba RAS-10GAVP-E Specifications

General IconGeneral
BrandToshiba
ModelRAS-10GAVP-E
CategoryAir Conditioner
LanguageEnglish