Item
16. Clean operation
release
Operation flow and applicable data, etc.
Setting the clean operation release
Description
* J04 will be near the MCU so take
steps to ensure that it will not be
exposed to excessive levels of
heat.
Also take care to avoid solder
bridging with the surrounding
components.
Setting the clean operation
Indoor P.C. board
Add J04 of the indoor P.C. board assembly.
* This cancels the auto restart function.
Hold down the auto operation switch on the indoor unit
for at least 3 seconds but not more than 10 seconds.
The indoor units buzzer emits three beeps, and
the OPERATION indicator flashes at 5 Hz intervals.
This completes the clean operation release setting.
Cut J04 of the indoor P.C. board
* This step may be skipped if the auto restart function
is not required.
Hold down the auto operation switch on the indoor unit
for at least 3 seconds but not more than 10 seconds.
The indoor units buzzer emits three beeps, and
the OPERATION indicator flashes at 5 Hz intervals.
This completes the clean operation setting.
J04

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba RAS-10GAVP-E and is the answer not in the manual?

Toshiba RAS-10GAVP-E Specifications

General IconGeneral
BrandToshiba
ModelRAS-10GAVP-E
CategoryAir Conditioner
LanguageEnglish

Related product manuals