19
1-1-2. 4-Way Cassette
<Single type>
Model
Indoor unit RAV-RM 561UTP* 801UTP*
Outdoor unit RAV-GP 561ATW* 801ATW*
Cooling capacity (kW) 5.0 7.1
Heating capacity (kW) 5.6 8.0
Power supply 220 - 240 V ~, 50 Hz
(Power supply from outdoor unit)
Electrical
characteristics
Cooling Running current (A) 6.04-5.54 7.72-7.08
Power consumption (kW) 1.22 1.58
Power factor (%) 93 93
EER 4.10 4.49
SEER 7.61 8.80
Energy efficiency class (Lot10) A++ A+++
Heating Running current (A) 6.33-5.80 8.56-7.85
Power consumption (kW) 1.30 1.77
Power factor (%) 93 94
COP 4.31 4.52
SCOP 4.96 5.22
Energy efficiency class (Lot10) A++ A+++
Maximum current (A) 13.1 20.3
Indoor unit
Fan unit
Fan Turbo fan Turbo fan
Standard air flow (H/M+/M/L+/L) (m³/min) 17.5/-/14.5/-/13.0 20.5/-/16.0/-/13.5
Motor (W) 14 20
Sound pressure level (H/M+/M/L+/L) (dB(A)) 32/-/29/-/28 35/-/31/-/28
Sound power level (H/M+/M/L+/L) (dB(A)) 47/-/44/-/43 50/-/46/-/43
Outdoor unit
Length of refrigerant
pipe
Max. total length (m) 50 50
Min. length (m) 3 3
Height
difference
Outdoor lower (m) 30 30
Outdoor high (m) 30 30
Fan unit
Fan Propeller fan Propeller fan
Standard air flow high (m³/min) 37.5 53
Motor (W) 43 60
Connecting pipe
Outdoor unit-
Pipe branch
Gas side (mm) 12.7 15.9
Liquid side (mm) 6.4 9.5
Pipe branch-
indoor unit
Gas side (mm) 12.7 15.9
Liquid side (mm) 6.4 9.5
Sound pressure level Cooling/Heating (dB(A)) 46/48 46/48
Sound power level Cooling/Heating (dB(A)) 63/65 63/66