113
13-2.RAV-GP801ATW*
No. Part name Procedure Remarks
(1) Common
procedures
Front panel
Top cover
Stop operation of the air conditioner and turn off breaker
switch.
Ensure wearing of gloves when performing any work in
order to avoid injury from parts, etc.
1. Detachment
1)Stop operation of the air conditioner, and turn off the
main switch of the breaker for air conditioner.
2)Remove the front panel.
(3 pcs, M4 × 10 hexagon screws)
(1)After removing the screws slide the front panel
downwards.
(2)Pull the front panel forwards and then loosen the
right claw.
(3)Pull the front panel to the right, loosen the left
claw, and then remove the front panel.
3)Remove the terminal cover.
(2 pcs, M4 × 8 truss screws)
4)Remove the power and indoor / outdoor connection
wires from the cable-ties and terminals.
5)Remove the top cover.
(6 pcs, M4 × 10 hexagon screws)
Front panel
Left cl
Left clawLeft claw
Right clRight claw
Right claw
Screws
Claw
T
minal c
v
Terminal cover
Ground connection
for inside and outside
Clamp filter
Terminal