Page #6 background image
RLC-SVX19A-E4
6
Digit 1, 2, 3, 4 – Unit model
RTAF = Air-Cooled Chiller
Digit 5, 6, 7 – Unit size
090 = 090 Tons
105 = 105 Tons
125 = 125 Tons
145 = 145 Tons
155 = 155 Tons
175 = 175 Tons
190 = 190 Tons
205 = 205 Tons
Digit 8 – Unit voltage
D = 400V/50Hz/3ph
Digit 9 – Manufacturing Location
E = Europe
Digit 10,11 – Design sequence
A0 = Factory assigned
Digit 12 – Effi ciency level
N = Standard Effi ciency (SE)
H = High Effi ciency (HE)
A = eXtra Effi ciency (XE)
V = High Seasonal Effi ciency (HSE)
Digit 13 – Agency listing
C = CE Marking
U = UL Certifi ed
Digit 14 – Pressure vessel code
2 = PED (Pressure equipment directive)
Digit 15 – Acoustic level
X = Standard noise (SN)
L = Low noise (LN)
Q = Low Noise with Night Noise SetBack (NNSB)
E = Extra Low Noise (XLN)
Digit 16 – Operating map : airside
X = Standard ambient
L = Low ambient
H = High ambient
Digit 17 – Relief valve option
L = Single relief valve high & low Pressure side
D = Dual relief valve with 3 way valve high pressure &
low pressure side
Digit 18 – Water connection
X = Grooved pipe connection
W = Grooved pipe with coupling and pipe stub
Digit 19 – Operating map water side
N = Comfort cooling (above 4.4°C)
P = Process cooling (below 4.4°C)
C = Ice Making (-7°C to 20°C)
Digit 20 – Evaporator Confi guration
2 = Two pass evaporator
T = Two pass evaporator with turbulators
Digit 21 – Thermal Insulation
N = Standard
H = High performance
X = None
Digit 22 – Condenser coating
N = Aluminum micro channel
C = E-Coated Micro channel
Digit 23 – Open for future use = X
Digit 24 – Hydraulic module
X = Pump signal On/Off
1 = Dual pump standard pressure
3 = Dual pump high pressure
Digit 25 – Open for future use = X
Digit 26 – Disconnect switch
F = With Fuse
B = With circuit breaker
Digit 27 – Under/over Voltage
X = None
1 = Included
2 = Included with ground fault protection
Digit 28 – Human Interface language
C = Spanish
D = German
E = English
F = French
H = Dutch
I = Italian
M = Swedish
P = Polish
R = Russian
T = Czech
U = Greek
V = Portuguese
2 = Romanian
6 = Hungarian
8 = Turkish
Digit 29 – Smart com protocol
X = None
B = Bacnet interface
M = Modbus interface
L = LonTalk interface
Digit 30 – Communication customer
X = None
A = External set point & capacity outputs
Digit 31 – Flow switch
X = None
F = Field installed fl ow switch
Unit Model Number Description

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane RTAF SE Series and is the answer not in the manual?

Trane RTAF SE Series Specifications

General IconGeneral
BrandTrane
ModelRTAF SE Series
CategoryChiller
LanguageEnglish

Related product manuals