Model Number Descriptions
6 UNT-SVX07J-EN
4 = Heat pump, Auxiliary electric
heat
5 = DX cooling
6 = DX cooling, Electric preheat
Digit 19 — Drain Pan
0 = None - Electric heat only
3 = Polymer drain pan
4 = Stainless steel drain pan
Digit 20 — Air Vent
0=None
A = Automatic
M= Manual
Digits 21, 22, 23 — Electric Heat
kW
000= None
010 = 1.0 kW (0.75 kW 208 V)
015 = 1.5 kW (1.1 kW 208 V)
020= 2.0 kW (1.5 kW 208 V)
025= 2.5 kW (1.9 kW 208 V)
030= 3.0 kW (2.2 kW 208 V)
040= 4.0 kW (3.0 kW 208 V)
045= 4.5 kW (3.3 kW 208 V)
050= 5.0 kW (3.7 kW 208 V)
060= 6.0 kW (4.4 kW 208 V)
070= 7.0 kW (5.3 kW 208 V)
075= 7.5 kW (5.7 kW 208 V)
080= 8.0 kW (6.0 kW 208 V)
090= 9.0 kW (6.6 kW 208 V)
100 = 10.0 kW (N/A 208 V)
105 = 10.5 kW (7.9 kW 208 V)
110 = 11.0 kW (9.0 kW 208 V)
120= 12.0 kW (N/A 208 V)
135= 13.5 kW (10.2 kW 208 V)
150= 15.0 kW (N/A 208 V)
180= 18.0 kW (13.5 kW 208 V)
200= 20.0 kW (15.0 kW 208 V)
200= 21.0 kW (15.0 kW 208 V)
220= 22.0 kW (16.4 kW 208 V)
Digit 24 — Reheat Coil
0 = Without reheat
A = Steam reheat (4 FPI)
B = Hot water reheat (4 FPI)
D = High capacity hot water reheat
(12 FPI)
Digit 25 — Unit Mounted
Disconnect Switch
0=None
D = With disconnect switch
Digit 26 — Filter Type
0=None
1 = 1-in. throwaway
2 = 1-in. throwaway MERV 8
3 = 1-in. throwaway, one extra
4 = 1-in. throwaway MERV 8,
one extra
5 = 1-in. throwaway, two extras
6 = 1-in. throwaway MERV 8,
two extras
7 = 1-in. throwaway, three extras
8 = 1-in. throwaway MERV 8,
three extras
A = 1-in. throwaway MERV 13
B = 1-in. throwaway MERV 13,
one extra
C = 1-in. throwaway MERV 13,
two extras
D = 1-in. throwaway MERV 13,
three extras
Digit 27 — Future Option
0=None
Digit 28 — Future Option
0=None
Digit 29 — Piping Packages
0=None
A = Basic - Ball valve supply and
return
B = Basic - Ball valve supply and
manual circuit setter return
E = Deluxe - Ball valve supply and
manual circuit setter return
F = Deluxe - Ball valve supply and
return with auto flow
Digit 30 — Control Type
A = Fan speed control
E = Tracer® ZN010
F = Tracer® ZN510
G = Tracer® ZN520
H = Customer Supplied Terminal -
STAT Interface (CSTI)
L = Tracer® UC400-B
M = Tracer® UC400-B with
Wireless Communications
Interface (WCI)
N = CSTI with fan status
Digit 31 — Control Options
0=None
V = Unit-mounted zone sensor
module (OALMH and Setpoint
dial)
W = Wall-mounted zone sensor
module (OALMH and Setpoint
dial)
X = Unit-mounted fan mode switch,
Wall-mounted zone sensor
(Setpoint dial)
Y = Unit-mounted fan mode switch,
Wall-mounted zone sensor
(Setpoint dial, On/CANCEL,
Comm. jack)
Z = Unit-mounted zone sensor
module (OALMH, Setpoint dial,
On/CANCEL buttons)
1 = Wall-mounted zone sensor
module (On/CANCEL buttons,
Comm. jack)
2 = Wall-mounted zone sensor
module (OALMH, Setpoint dial,
On/CANCEL, Comm. jack)
4 = Wall-mounted digital zone
sensor (O/A/H/M/L, Setpoint dial,
On/CANCEL, Comm. jack)
6 = Wireless zone sensor (Setpoint
dial, Occupied/Unoccupied
buttons)
7 = Wireless display sensor, Unit-
receiver (OALMH)
8 = Unit-mounted variable speed
control
9 = Wall-mounted variable speed
control
Digit 32 — IAQ Options
0=None
1 = Dehumidification
2 = VOC/CO
2
3 = Dehumidification and VOC/CO
2
4 = Dehumidification with sensor
5 = Air-Fi® Dehumidification and
VOC/CO
2
6 = Air-Fi® Dehumidification with
sensor
7=Air-Fi® CO
2
Digit 33 — FLA Motor Options
0 = Standard ECM
A = Reduced FLA
Digit 34 - Control Options
0 = None
A = Low limit sensor
B = Condensate overflow
C = Low limit and condensate
overflow
Digit 35 — Main Valve Type
0=None
A = 2-way, 2-position N.C
B = 2-way, 2-position N.O
C = 3-way, 2-position N.C
D = 3-way, 2-position N.O
E = 2-way, Modulating
F = 3-way, Modulating
G = 2-way, Analog (2-10 VDC)
H = 3-way, Analog (2-10 VDC)
J = Field supplied, 2-position N.C
K = Field supplied, 2-position N.O
L = Field supplied, Modulating
M = Field supplied, Analog (2-10
VDC)
Digit 36 — Cv Main Valve
0=None
A = 2-way 1.4 Cv
B = 2-way 2.4 Cv
C = 2-way 3.4 Cv
D = 3-way 1.0 Cv
E = 3-way 2.7 Cv
F = 3-way 4.6 Cv
Digits 37 — Auxiliary Valve Type
0=None
A = 2-way, 2-position N.C.
B = 2-way, 2-position N.O.
C = 3-way, 2-position N.C.
D = 3-way, 2-position N.O.
E = 2-way, Modulating
F = 3-way, Modulating
G = 2-way, Analog (2-10 VDC)
H = 3-way, Analog (2-10 VDC)
J = Field supplied, 2-position N.C.
K = Field supplied, 2-position N.O.
L = Field supplied, Modulating
M = Field supplied, Analog (2-10
VDC)
Digits 38 — Cv Auxiliary Valve
0=None
A = 2-way 1.4 Cv
B = 2-way 2.4 Cv
C = 2-way 3.4 Cv
D = 3-way 1.0 Cv
E = 3-way 2.7 Cv
F = 3-way 4.6 Cv

Table of Contents

Other manuals for Trane UniTrane

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane UniTrane and is the answer not in the manual?

Trane UniTrane Specifications

General IconGeneral
BrandTrane
ModelUniTrane
CategoryHeater
LanguageEnglish

Related product manuals