40V
400V
1000V/~750V
mA
Range Signal Requirement Frequency Range
4V 1.0V 5Hz~10kHz
5.0 5Hz~20kHz
45V 45Hz~4kHz
420 45Hz~1.6kHz
45mA 5Hz~5kHz
Measurement Operation (8)
A
l
To obtain a stable reading when measuring input scope
30V rms frequency signal:
Set the rotary switch to V .
Then press Hz% to select Hz measurement mode to
obtain frequency value.
When input scope 30V rms, please follow the above
step 2. carrying out the measurement.
l When making frequency measurement at voltage or current
range, please mind the following signal requirement table:
4A 45Hz~1kHz
l
To obtain a stable reading when measuring input scope
30V rms frequency signal:
Set the rotary switch to V .
Then press Hz% to select % measurement mode to
obtain
duty cycle value.
When input scope 30V rms, please follow the above
step 2. carrying out the measurement.
H. Measuring Duty Cycle (See figure 9)
The duty cycle measurement range is: 0.1%~99.9%. To
measure duty cycle, do the following:
1. Set up the Meter to measure frequency.
2. To select duty cycle, press Hz % until the % symbol is shown
on the display.
3. Connect the test leads across with the object being measured.
The measured value shows on the display.
Note
l The LCD displays 000.0% indicating the input signal is high
or low level.
l When duty cycle measurement has been completed,
disconnect the connection between the testing leads and the
circuit under test, and remove the testing leads away from the
input terminals of the Meter.
21
Model UT60B/C/E: OPERATING MANUAL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT60E and is the answer not in the manual?

UNI-T UT60E Specifications

General IconGeneral
BacklightYes
Product typeDigital multimeter
Frequency range0.01 - 10000 kHz
AC current range0.4 - 10 A
AC voltage range4 - 750 V
DC voltage range0.4 - 1000 V
Dimensions (WxDxH)85 x 177 x 40 mm
Battery voltage9 V
Weight and Dimensions IconWeight and Dimensions
Weight320 g

Related product manuals