20
Measurement Operation(4)
Use the 10A terminal and A range if the current
value to be tested is an unknown.
Model UT60F has 3 measurement positions on
the rotary switch: µA , mA and A .
Model UT60G has 2 measuremnet positions on
the rotary switch: mA and A .
To measure current, do the following:
1. Model UT60F: Insert the red test lead into the
µAmA or 10A terminal and the black test lead
into the COM terminal.
Model UT60G: Insert the red test lead into the
mA
o
C or 10A terminal and the black test lead
into the COM terminal.
2. Set the rotary switch toµA , mA, or A The
Meter defaults to DC current measurement
mode. To toggle between DC and AC current
measurement function, press the BLUE button.
3. Connect the test leads with the object being
measured.
The measured value shows on the display
Note:
l For safety sake, the measuring time for high
current should be less than 10 seconds for
each measurement and the interval time
between 2 measurements should be greater
than 15 minutes.
l When current measurement has been
completed, disconnect the connection between
the testing leads and the circuit under test
and remove testing leads from the input
terminals.
Model UT60F/G: OPERATING MANUAL