EasyManuals Logo
Home>Unitech>Barcode Reader>MS836

Unitech MS836 User Manual

Unitech MS836
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Image Stabilization Timeout: The scanner
waits for the image stabilization timeout
to expire before activating a decode session
every time it detects a change in ambient
illumination. This parameter is programmable
in 0.1s increments from 0.0s to 25.5s. The
default timeout is 0.4s.
Image Stabilization
Timeout
M00031B
Example: Set the Image Stabilization Timeout to
5s
1.
Scan the Enter Setup barcode.
2.
Scan the Image Stabilization Timeout
barcode.
3. S
c
a
n
t
h
e
num
e
ri
c
b
a
r
c
od
e
s
5
a
n
d
0
”.
(See the Digit Barcodes section in Appendix)
4.
Scan the Save barcode. (See the
Save/Cancel Barcodes section in Appendix)
5.
Scan the Exit Setup barcode.
Reread Delay sets the time period before the
scanner can read the same barcode a second time.
It protects against accidental rereads of the
same barcode. This parameter is programmable
in 0.1s increments from 0.1s to 25.5s. The default
delay is 3.0s. If the parameter is set to 0, the delay is
infinite.
Note: This parameter only applies when the
Reread Same Barcode with a Delay is enabled.
Reread Delay
M00031E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unitech MS836 and is the answer not in the manual?

Unitech MS836 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength650 nm
Sensor typeLaser
Scanner type1D
Read rate (max)100 reads/s
Maximum scan area220 x 250 mm
Maximum scan width220 mm
Linear (1D) barcodes supportedCodabar, Code 128, Code 39, EAN-13, EAN-8, GS1-128 (UCC/EAN-128), Interleaved 2 of 5, MSI, U.P.C.
2D (matrix & stacked) barcodes supportedNot supported
Standard interfacesUSB
Connectivity technologyWired
Power consumption85 mA
BuzzerYes
CertificationCE, FCC
Product colorBlack
Housing materialPlastic
International Protection (IP) codeIP42
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 45 °C
Operating relative humidity (H-H)5 - 85 %
Weight and Dimensions IconWeight and Dimensions
Depth95 mm
Width70 mm
Height160 mm
Weight150 g