C740A10 24V voltage is
outside of the
allowed range
Same as C740A
C740A11 48V voltage is
outside of the
allowed range
Same as C740A
C740A12 58V voltage is
outside of the
allowed range
Same as C740A
C740A13 -4V voltage is
outside of the
allowed range
Same as C740A
C740A14 Robot voltage is
outside of the
allowed range
Same as C740A
C740A15 Robot current is
outside of the
allowed range
Same as C740A
C740A17 Inrush protected 48V
voltage is outside of
the allowed range
Same as C740A
C740A20 24V SPI IO voltage 24V voltage IO is outside its
limits
(Below 23,0V above 25,7V)
a) Do a Complete rebooting
sequence
b) Check for loose
connections
c) Check for damages to the
Tool/sensor
d) Update software
e) Contact your local
Universal Robots service
provider for assistance
C740A21 24V SPI IO current 24V current IO is outside its
limits
a) Do a Complete rebooting
sequence
b) Check for loose
connections
c) Check for damages to the
Tool/sensor
d) Update software
e) Contact your local
Universal Robots service
provider for assistance
UR5 198 Service Manual
7.Troubleshooting
Copyright © 2009–2021 by UniversalRobotsA/S. All rights reserved.

Table of Contents

Other manuals for Universal Robots UR5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots UR5 and is the answer not in the manual?

Universal Robots UR5 Specifications

General IconGeneral
BrandUniversal Robots
ModelUR5
CategoryRobotics
LanguageEnglish

Related product manuals