2 Attention messages and alarms
III UWATEC
®
Smart dive computers
TEC draws the diver’s attention to certain situations and warns the diver of unsafe diving practices. Atten-
tion messages and alarms are always visual and audible under water, only visual at the surface except the
decompression alarm.
The audible attention messages (but not the alarms) can be selectively
switched off with SmartTRAK.
III
English
2.1 Attention messages
Attention messages are communicated to the
diver visually by symbols, letters or flashing figu-
res. In addition, two short audible sequences can
be heard (in an interval of 4 seconds) in two diffe-
rent frequencies under water.
Attention messages come up in the following
situations (more information can be found on the
listed pages):
Page
Maximum Operating Depth / max ppO
2
is reached 20
Set maximum depth is reached 19
Oxygen toxicity reaches 75% 21
No-stop time = 2 minutes 22
Prohibited altitude* (surface mode) 25
Entering decompression when diving with L0
23
Remaining Bottom Time < 3 minutes 22
Tank pressure has reached set warning level 21
Increased workload 21
Depth for tank switch has been reached 35
Diving with microbubble levels (L1-L5):
MB no-stop time = 0 30
MB level stop ignored 31
MB level reduced 31
Entering decompression when diving
with MB level L1-L5 31
*without audible alarm
4 sec
2.2 Alarms
Serious injury or death may result from failing to
immediately respond to alarms given by TEC.
Alarms are given to the diver visually by flashing
symbols, letters or figures. In addition, an audible
sequence in one frequency can be heard during
the whole duration of the alarm.
An alarm occurs in the following situations
(more information can be found on the listed
pages):
Page
Oxygen toxicity reaches 100% 21
Ignored decompression 23
Remaining Bottom Time = 0
( can be switched to attention beep) 22
• Exceeding the prescribed ascent rate 20
(Particular scale of beeps, ->20)
• Low battery alarm* see below
Low battery alarm TEC*
The service symbol appears if the battery capacity
reaches 0%.
Take the unit to your
authorised SCUBAPRO
UWATEC retailer.
Transmitter battery low: *
<bAt> flashing and alternating with the display of
the tank pressure.
Replace the battery in
the transmitter. ->40
*without audible alarm
(can be switched off)
(can not be switched off)
%
NO STOP
NO STOP
WARNING