EasyManuals Logo
Home>Uwatec>Diving Instrument>SMART TEC

Uwatec SMART TEC User Manual

Uwatec SMART TEC
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
30
3 Preparation for a dive with microbubble levels (MB levels)
V UWATEC
®
Smart dive computers
3.1 Setting the MB level
To change the MB level TEC must be in user mode.
1. Bridge contacts B and + or B and – until the symbol for MB levels appears.
2.
Confirm that you wish to change the displayed MB level by bridging B and E.
3. Change MB level by bridging contacts B and + or B and – .
4. Confirm with B and E the selected MB level.
Without confirmation the display will disappear after 3 minutes and your
entries will not be accepted.
TEC will display the symbol to confirm that an MB level beyond L0 (L1-L5)
has been chosen. During the dive the MB level is shown by pressing briefly
. If however a level stop is ignored, the new MB level is permanently
shown (->31).
MB levels have an influence on the dive planner.
4 Functions during the dive with microbubble levels
4.1 Level stop information
Microbubble (MB) no-stop time
While diving with MB levels L1 to L5 TEC will display the MB no-stop time instead of the ordinary no-stop
time. Within the MB no-stop time no level stops are required.
The arrow and the MB level symbol are visible. The remaining MB no-stop time is shown
in minutes.
Information and alarms for MB no-stop time and ordinary no-
stop time are the same (->22).
Regardless of the MB level, we generally recommend to perform
a slow ascent during the last few metres / feet.
Level stop
On entering the level stop phase, the arrow disappears and the
arrow
appears. The arrow flashes for 8 seconds and an
audible attention beep goes off. To complete the dive without being reduced
to a lower MB level, all requested level stops must be observed.
To the right of the arrow, the deepest level stop is displayed in met-
res/feet. The display <3m 2:> (<10ft 2:>) means that a level stop of 2 minutes
at a depth of 3 metres (10ft) has to be observed.
When a level stop obligation is finished, the next higher level stop – if present
– is displayed. When all level stops have been observed, the arrow
extinguishes and the arrow reappears. The indication of time shows
the MB no-stop time again.
NO STOP
LEVELSTOP
LEVELSTOP
LEVELSTOP
LEVELSTOP
NO STOP
NO STOP
NO STOP
MB no-stop time
+
LEVELSTOP
CNS O
2
%
Deepest level
stop depth
Total ascent time
Level stop duration
Level stop icon

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uwatec SMART TEC and is the answer not in the manual?

Uwatec SMART TEC Specifications

General IconGeneral
BrandUwatec
ModelSMART TEC
CategoryDiving Instrument
LanguageEnglish

Related product manuals