DHP-UM-020
Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 Fax +45 7547 0611
vc@valcontrols.com www.valcontrols.com
Revision: 12
18/38
Valve action
Menu to select the Control loop to be Direct or Reverse.
Direct : Valve opens with increasing set point value
Reverse : Valve closes with increasing set point value
Regulator
Menu to set whether the regulator should keep opening or closing when within the deadband of 0%
and 100%
End settings
Hold at Open:
o Status:
Off: Never hold
On: Hold after the number of seconds specified in the next menu
o Time: 0-30 sec. Do not have any effect if Status is Off
Hold at Open:
o Status:
Off: Never hold
0
25
50
75
100
0 25 50 75 100
Flow - %
Travel - %
0
25
50
75
100
4 8 12 16 20
Flow - %
Control loop - mA
0
25
50
75
100
4 8 12 16 20
Flow - %
Control loop - mA