Warning! To comply with FCC and IC RF exposure compliance requirements, the device should be located at a distance of at least 20 cm from all
persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other antenna or
transmitter.
Warning! The user is cautioned that changes or modifications to the unit, not expressly approved by Visonic Ltd., could void the user’s FCC or other
authority to operate the equipment.
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then
you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.
APPENDIX: SPECIFICATIONS
Frequency
Band (MHz)
Europe and rest of world: 433-434, 868-869 USA:912-919
Maximum
Tx Power
10 dBm @ 433 MHz, 14 dBm @ 868 MHz
Communication
Protocol
PowerG
Alarm Input
One auxiliary
Tamper
Front and back
Supervision
Signaling at 4-min. intervals
Tamper Alert
Reported when a tamper event occurs
Power Supply
Type C
Battery type
3 V Lithium CR-123A type battery, Panasonic, Sanyo or GP only.
Battery Life
Expectancy
5 years (for typical use) with all sensors enabled
Low Battery
Threshold
2.6 V
Current
Consumption
20-30 μA approx. (150 mA during transmission)
Shock
Detection
Radius
Not EN Tested EN Certified (CLC/TS 50131-2-8)
Window 4m
(13 ft)
Framed glass window
(Standard test material A1)
1 m
(3.3 ft)
Wood 3.5m
(11.5 ft)
Wood (Standard test material A2) 1 m
(3.3 ft)
Brick/concrete
walls
2.5m
(8.2 ft)
Concrete (Standard test material A3) 0.5 m
(1.6 ft)
Note: Different materials vary in density, size, and thickness, so it is impossible to
guarantee that certain values apply to all options. The provided values that are not EN
tested are given as possible values. The ENcertified values are the minimum values that
EN requires for surfaces with predefined parameters, mentioned as A1, A2, or A3
materials.
Operating
Temperature
-10°C to 55°C (14°F to 131°F)
Storage
Temperature
-20°C to 60°C (-4°F to 140°F)
Humidity Average relative humidity of approximate 75% non-condensing. For 30 days per year relative humidity may vary between 85 % and
95 % non-condensing
Auxiliary Input
Cable Length
10m max.
Auxiliary Input
EOL Resistor
2.2 KΩ
Dimensions
(LxWxD)
118 x 27 x 30 mm (4-5/8 x 1-1/8 x 1-3/16 in.)
Weight
(including
battery)
130g (4.6 oz)
D-304286 SD-304C PG2 Installation Instructions 6