Diagnostic Trouble Codes Group 30: Electrical system
34
MID 128, PID 45
Inlet air heater status
MID 128: Engine control unit
FMI 3: The voltage exceeds the normal value or is
short circuited to higher voltage.
FMI 4: The voltage is less than the normal value or
is short circuited to lower voltage.
FMI 5: The current is less than the normal value or
is open circuited.
FMI Fault code explanation
3, 4, 5 Faulty sensor / Faulty sensor circuit
Fault indication
DCU: Engine warning in DCU display.
CIU: Flash code
Flash code
Electrical fault: 5.4
Value fault: None
Symptom
FMI 3, 5: Preheat relay never activated. White
smoke for cold start. Start problems in
cold climate.
FMI 4: Induction air is hot. Preheat relay is im-
possible to turn off. Preheat fuse will
break.