11 Maintenance
100_0202_mt_0005.fm 31
11.1.3 Regular maintenance
Maintenance work Monthly Every
150 hours
Every
250 hours
Every
500 hours
Every
1000 hours
Check exciter oil - fill if neces-
sary.
Check hydraulic oil - fill if nec-
essary.
Check the V-belt tension - tight-
en as needed.
Check that the fastening
screws are tight:
Protective frame.
Central suspension.
Check exciter oil - fill if neces-
sary.
Change engine oil.
Change exciter oil. *
* Have these tasks carried out by the service department of your Wacker Neuson contact person.
Check that the fastening
screws are tight:
Drive motor. *
Check the valve clearance, set
to 0.10 mm when the engine is
cold. *
Replace the fuel filter. *
Replace air cleaner.
Clean oil filter. *