8 Operation and use
100_0202_op_0011.fm 32
8.3.2 Commission machine (center pole)
1. The red control lamp on the center pole flashes briefly at intervals of 5 seconds to signal readiness
to start.
2. Briefly press start button of the center pole – the motor will start automatically.
8.3.3 Commission machine (remote control)
Switch on remote control unit
1. Press the ON/OFF switch of the remote control unit Operation-control lamp flashes green when the
remote control is switched on.
2. Hang the remote control with the carrying strap.
Item Designation Item Designation
1 Start button 2 Control lamp
NOTE
The starting process can take up to 2 minutes. As long as the control lamp is red, the
automatic start up runs. Depending on the operating temperature of the engine, the glow
plugs are optionally preheated and warmed up.
Item Designation Item Designation
1 Control lamp for operation 2 ON/OFF switch
NOTE
If the operation-control lamp flashes or lights red, recharge the rechargeable battery.
1
2
1
2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson DPU Series and is the answer not in the manual?

Wacker Neuson DPU Series Specifications

General IconGeneral
BrandWacker Neuson
ModelDPU Series
CategoryPower Tool
LanguageEnglish

Related product manuals