10 Troubleshooting
100_0202_ts_0010.fm 52
10 Troubleshooting
10.1 Troubleshooting table – machine
DANGER
Unauthorized troubleshooting can be life threatening.
In the case of any faults that do not appear in this manual, please contact the
manufacturer. Do not try to rectify them yourself.
Fault Possible causes Remedial measure
Motor will not start. Emergency shutdown switch is
pressed.
Unlock emergency shutdown
switch.
Air cleaner is dirty. Replace air cleaner.
Machine is not activated. Activate machine.
Discharge starter battery. Load starter battery or perform
jump-start with donor starter.
Low oil level. Top up oil and actuate valve hood
on the oil filter housing.
Low fuel. Top up fuel.
Fuel filter is dirty. Replace fuel filter.*
Defective starter motor. Have the machine repaired.*
Remote control, decoder, or wiring
harness is defective.
Engine runs unevenly. Fuel filter is dirty. Replace fuel filter.
Air cleaner is dirty. Clean or replace air cleaner.
Vibration will not start. Electrical system defective. Have the machine repaired.*
Engine smokes and does not
perform.
Air cleaner is dirty. Replace air cleaner.
Another machine is controlled by
the remote control.
Both machines are set to the same
transmission channel.
Set one of the machines to a
different transmission channel.
Machine cannot be deactivated. Incorrect activation PIN entered. Enter the correct activation PIN.
Deactivate machine with
emergency shutdown switch.
Electrical system defective. 1. Deactivate machine with
emergency shutdown switch.
2. Have the machine repaired.*
Diagnostics menu cannot be called
up.
ON/OFF switch of the machine not
pushed long and/or hard enough.
Continuously press the ON/OFF
switch of machine for at least three
seconds.
Compatec - compaction display
(optional):
If all LEDs permanently flash after
initialization, the sensor has not
been successfully tested.
Switch-on with the engine running. Have the machine repaired.*
Sensor is defective.
*
Have this work done by the service of Wacker Neuson.