9 Maintenance
51 100_0202_mt_0011.fm
9.4.8 Check hydraulic oil level and top up hydraulic oil
Check hydraulic oil level
1. Open both protective hoods.
2. Check whether the hydraulic oil reaches the upper edge of the oil level glass.
Top up hydraulic oil
3. Remove dirt accumulation in the area of the hydraulic oil tank.
4. Unscrew and remove cover of the hydraulic oil tank.
5. Top up hydraulic oil until the hydraulic oil reaches the middle of the oil level glass – for oil
specification, see Technical Data chapter.
6. Replace cover of the hydraulic tank and tighten (torque setting of 10 Nm) – make sure that the seal
of the cover fits properly.
9.4.9 Screwed connection
For the vibratory plates, the screwed connections must be regularly checked for tightness.
Item Designation Item Designation
1 Cover of the hydraulic oil tank 2 Oil level glass
NOTE
If the machine is losing hydraulic oil, check the hydraulic line for leaks, and have the
machine repaired by the service of the Wacker Neuson contact person.
WARNING
Hot hydraulic oil can cause injury by scalding.
Do not open the cover of the hydraulic oil tank while the hydraulic oil is still hot.
Let the machine cool.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson DPU Series and is the answer not in the manual?

Wacker Neuson DPU Series Specifications

General IconGeneral
BrandWacker Neuson
ModelDPU Series
CategoryPower Tool
LanguageEnglish

Related product manuals