7-48 BA D18 us* 1.1 * D18w710.fm
7 Maintenance
Manual regeneration
Starting manual regeneration
Indicator light B illuminates and indicator light E flashes.
➥ Manual regeneration is possible only in this case and has to be started.
1. Travel the machine out of the danger zone and into a safe area.
2. Apply the parking brake.
3. Press and hold push button A at least 10 seconds in position 3.
➥ Indicator lights B and C illuminate during regeneration.
Interrupting manual regeneration
Press and hold the Regeneration push button at least 3 seconds in
position 1.
Possible damage to engine or particulate filter.
► Perform a complete regeneration cycle.
Fire hazard at the exhaust system.
► There must be no easily flammable material in the direct vicinity of the
exhaust system, in particular near the end pipe.
► Do not perform manual regeneration in environments with easily
flammable material.
Machine travel or operation is prohibited during manual regeneration.
► Do not leave the machine during regeneration.
Regeneration not performed – stopping the machine
Engine power is reduced if indicator lights B and F illuminate and if
indicator light E flashes.
Stop the engine immediately and contact a Wacker Neuson service
center.
7.22 Machine preservation
Machines are partly preserved at the factory (for example in the engine
compartment). Operation in an aggressive environment (for example salt
deposits) is prohibited.