4-34 BA D18 us* 1.1 * D18i400.fm
4 Putting into operation
Machine travel on public roads
1. Ensure that all legal requirements for machine travel on public roads
are fulfilled. This applies both to the machine and to the operator (for
example a corresponding driving license).
2. Lower the skip completely. If the machine is equipped with a swivel
skip, ensure in addition that the skip is in the middle position.
3. Lock the control lever see “Enabling/disabling the operating
hydraulics” on page 5-10.
4.5 Starting and stopping the engine
Preparations for starting the engine
WARNING
Accident hazard due to unintentional operation of the machine!
Unintentional operation can cause serious injury or death.
Only operate the machine from the seat with the seat belt fastened.
The starter cannot be actuated if the engine is already running (start
repeat interlock).
Do not run the starter for more than 30 seconds.
Wait two minutes so the battery can recover and the starter does not
overheat before trying again.
Information
Ensure sufficient ventilation during operation in enclosed premises.
Information
All controls must be within easy reach.
Fig. 93

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson DW100 and is the answer not in the manual?

Wacker Neuson DW100 Specifications

General IconGeneral
BrandWacker Neuson
ModelDW100
CategoryExcavators
LanguageEnglish

Related product manuals