EasyManuals Logo
Home>Wacker Neuson>Construction Equipment>IRFU Series

Wacker Neuson IRFU Series User Manual

Wacker Neuson IRFU Series
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
10 Maintenance
100_0101_mt_0001.fm 33
10.3 Maintenance work
Working in the workshop
Perform maintenance work in a workshop on a workbench. This has the following
benefits:
Protection of the machine of contamination on the construction site.
A level and clean work surface makes work easier.
There is a better overview over small parts and they are not lost as easily.
Visual inspection for damage
Check all machine parts and components for damage.
Check the tightness of the switch diaphragm for the ON/OFF switch.
Checking the wear dimensions of the vibrator head
Wear dimensions:
Minimum diameter of lower tube øL
L
Minimum diameter of vibrator head øL
Length of vibrator head L
L
Wear is highest at the end of the vibrator head.
Let the vibrator head be exchanged by your Wacker Neuson contact if the wear
dimensions are reached at a certain point.
Dimensions in bold are wear dimensions.
Dimensions in brackets are original dimensions of new ma-
chines.
WARNING
A damaged machine part, protective hose or power cable can result in personal
injury caused by electric current.
Do not operate a damaged machine.
Have a damaged machine repaired immediately.
Machine
type
Dimensions for vibrator head and lower tube
[mm]
øL
L
L
L
øL L
IR... 45 38 (45) 372 (382) 42 (45) 333
IR... 57 50 (58) 390 (400) 54 (58) 253

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson IRFU Series and is the answer not in the manual?

Wacker Neuson IRFU Series Specifications

General IconGeneral
BrandWacker Neuson
ModelIRFU Series
CategoryConstruction Equipment
LanguageEnglish