13 Technical data
56
100_0101_td_0001.fm
13.6 Extension cable
Only use permitted extension cables, see chapter Safety.
Refer to the following table for the required cross-section area of the exten-
sion cable:
Note: Refer to the nameplate or the chapter Technical data (via the item num-
ber) for the type designation and voltage rating of your machine.
WARNING
Electrical voltage.
Injuries from electrocution.
Check power cable and extension cable for signs of damage.
Only use extension cables for which grounded conductors are connected to
the plug and the coupling (only for machines of class rating I, see chapter
Technical Data).
Machine Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]
IRFU 30 120 1~ <
36 1,5
<
59 2,5
<
94 4,0
230 1~ <
136 1,5
IRFU 38 120 1~ <
22 1,5
<
37 2,5
<
59 4,0
230 1~ <
86 1,5
<
142 2,5
IRFU 45 120 1~ <
16 1,5
<
27 2,5
<
43 4,0
230 1~ <
63 1,5
<
104 2,5
<
150 4,0