13 Technical data
100_0101_td_0001.fm 57
Example
You utilize an IRFU 45/120 and want to use an extension cable with a length of
25 m.
The machine has an input voltage of 120 V.
According to the table, the extension cable must feature a cross-section area of
2.5 mm
2
.
IRFU 57 120 1~ < 13 1,5
<
22 2,5
<
34 4,0
230 1~ <
50 1,5
<
83 2,5
<
132 4,0
IRFU 65 120 1~ <
10 1,5
<
17 2,5
<
27 4,0
230 1~ <
30 1,5
<
50 2,5
<
79 4,0
Machine Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]
IRFU 30 120 1~ <
102 16
<
161 14
<
255 12
230 1~ <
391 16
<
500 14
Machine Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]