SERVICE MANUAL
VERSION 09/2017 ORDER NUMBER DOC2309350
Procedure:
1. Press "Standby" button 15. The yellow "Standby" LED 16 lights up.
2. Press “Characteristic Slope“ button 31 and hold it down.
3. With your other hand, turn the Universal rotary controller 24 clockwise until "10" is
shown in LED display 19.
4. Release the "Characteristic Slope" button 31.
5. The unit is now in con guration mode. The scrolling text "Con guration" is displayed
on LED display 19.
6. Press and hold "Pro le Part" button 7.
7. With your other hand, turn the Universal rotary controller 24 counterclockwise until
"930" is shown in LED display 19.
8. Release the "Pro le Part" button 7. Parameter C31 is selected.
9. Use "High-voltage" button 27 or "Current Limitation" button 29 to select parameter
C33 or C34.
8.3 ACCESSING THE SERVICE LEVEL C31C34