EasyManuals Logo
Home>WAGNER>Control Unit>EPG-Sprint X

WAGNER EPG-Sprint X Original Service Manual

WAGNER EPG-Sprint X
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
69
EPG-SPRINT / EPG-SPRINT X
Tribo
Corona
5
4
3
2
1
120
100
80
60
40
30
20
15
10
5
μA
μA
2x
kV
90
80
70
60
50
40
30
20
10
100
P_01271
24
19
16
15
312927
8
EPG
SPRINT X
0
%
kV
80
60
40
20
100
Tri Cor
5
4
3
2
1
120
80
40
20
10
2.0
μA
P_01830
24
19
16
15
312927
8
SERVICE MANUAL
VERSION 09/2017 ORDER NUMBER DOC2309350
Procedure:
1. Press "Standby" button 15. The yellow "Standby" LED 16 lights up.
2. Press “Characteristic Slope“ button 31 and hold it down.
3. With your other hand, turn the Universal rotary controller 24 clockwise until "10" is
shown on LED display 19.
4. Release the "Characteristic Slope" button 31.
5. The unit is now in con guration mode. The scrolling text "Con guration" is displayed
on LED display 19.
6. Press and hold "Double Click" button 8.
7. With your other hand, turn the Universal rotary controller 24 clockwise until "123" is
shown in LED display 19.
8. Release "Double-Click" button 8. Parameter C41 is selected.
9. Use "High-voltage" button 27 or "Current Limitation" button 29 to select parameter C42,
C43, C44 or C45.
10.2 ACCESSING THE PLANT LEVEL PARAMETERS

Table of Contents

Other manuals for WAGNER EPG-Sprint X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-Sprint X and is the answer not in the manual?

WAGNER EPG-Sprint X Specifications

General IconGeneral
BrandWAGNER
ModelEPG-Sprint X
CategoryControl Unit
LanguageEnglish

Related product manuals