10.7 PARAMETER C45, DEFAULT SETTING OF OFFSET FOR AIR CHANNELS
Purpose:
In standard operation of the unit, it automatically performs a repeating o set correction
(automatic o set correction) of the air channels. But it can be performed only in certain
limits, otherwise it triggers a fault message. With the presetting of the o set described
below, the possible range of automatic o set correction is placed in the middle of the
range.
Procedure for the preparation:
1. Access parameter C45 (refer to Chapter 10.2).
2. Press the "Characteristic Slope" button 31. "no" is displayed on LED display 19.
3. Turn universal rotary controller 24 one step clockwise; "AFo" is indicated in the LED
display 19.
4. Press "Additional Recipes" button 25 for 1 second. The display goes out brie y as a
con rmation.
5. In step 0 (no LED is lit in the "High-voltage" LED display 1), the desired air channel
can now be selected by pressing the "Characteristic Slope" button 31.
Atomizing air Dosing air Feed air

Table of Contents

Other manuals for WAGNER EPG-Sprint X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-Sprint X and is the answer not in the manual?

WAGNER EPG-Sprint X Specifications

General IconGeneral
BrandWAGNER
ModelEPG-Sprint X
CategoryControl Unit
LanguageEnglish

Related product manuals