10.7 PARAMETER C45, DEFAULT SETTING OF OFFSET FOR AIR CHANNELS
Purpose:
In standard operation of the unit, it automatically performs a repeating o set correction
(automatic o set correction) of the air channels. But it can be performed only in certain
limits, otherwise it triggers a fault message. With the presetting of the o set described
below, the possible range of automatic o set correction is placed in the middle of the
range.
Procedure for the preparation:
1. Access parameter C45 (refer to Chapter 10.2).
2. Press the "Characteristic Slope" button 31. "no" is displayed on LED display 19.
3. Turn universal rotary controller 24 one step clockwise; "AFo" is indicated in the LED
display 19.
4. Press "Additional Recipes" button 25 for 1 second. The display goes out brie y as a
con rmation.
5. In step 0 (no LED is lit in the "High-voltage" LED display 1), the desired air channel
can now be selected by pressing the "Characteristic Slope" button 31.
Atomizing air Dosing air Feed air