EPG-SPRINT / EPG-SPRINT X
%
Tribo
Corona
5
4
3
2
1
120
100
80
60
40
30
20
15
10
5
μA
μA
0
10
20
30
40
50
60
70
80
90
100
Ø
12
10
11
9
8
m /h
5.0
4.0
3.0
2.0
6.0
3
5.5
4.5
3.5
2.5
2.2
2x
kV
90
80
70
60
50
40
30
20
10
100
m /h
4.0
3.0
2.0
1.0
0.5
0.4
0.3
0.2
0.1
1.5
EPG
S
PRIN
T
P_01111
28 27 30 29 31 32 37 35 2434 36 33
1 2 3 4 20 22 23 18 13 1921
12
8
11
7
10
6
9
25
26
16
17
15
14
5
SERVICE MANUAL
VERSION 09/2017 ORDER NUMBER DOC2309350
5.5 OPERATING ELEMENTS OF EPGSPRINT
5.5.1 OVERVIEW OF CONTROL PANEL FRONT SIDE
1 Illuminated display "High voltage"
Lights up green
Display range: 0-100 kV
Resolution 10 kV
Single LED display: Nominal voltage
Bar display: Working voltage
2 Illuminated display: "Corona or Tribo Current"
Lights up green
Tribo scale:
When a Tribo gun is connected and selected
Bar display: When powder feed is activated
Display range: 0-5 μA
Resolution 0.5 μA
Corona scale:
When a Corona gun is connected and selected
Display and adjusting range: 0 [5]-120 μA,
0 [5]-20 μA resolution 5 μA
20-40 μA resolution 10 μA
40-120 μA resolution 20 μA
Single LED display: "Trigger Point of Current Limitation"
Bar display: Corona current

Table of Contents

Other manuals for WAGNER EPG-Sprint X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-Sprint X and is the answer not in the manual?

WAGNER EPG-Sprint X Specifications

General IconGeneral
BrandWAGNER
ModelEPG-Sprint X
CategoryControl Unit
LanguageEnglish

Related product manuals