MultiControl | SmartControl | UniBox 16
9.2 Technician Mode
Service settings
This special function is not visible for the user and is only enabled
when the diagnostic adapter is connected. With this function, the
preset heaters with their settings can be selected and activated.
The limit values for temperature/heating time, etc., can be altered
by the technician in the event that they have not been correctly
preset for the installed system. Alternatively the settings can also
be altered using the WTT without diagnostic cable.
Factory settings may only be changed by qualified
personnel.
3
Connect the plug of the diagnostic cable to the control element.
3
Select the "Service" symbol in the main menu.
Press the control knob.
3
The "Quick-start" symbol appears on the display.
Select heater
This menu item allows a different heater to be selected. When a
different heater is selected, other settings from this menu are also
reset to the specific values for the heater. The error memory is also
deleted.
3
Select the "Service" symbol in the main menu.
3
The "Quick-start" symbol appears on the display.
Turn the control knob to select the desired symbol "Heater".
3
The name of the heater appears on the display.
Turn the control knob to select the heater.
Press the control knob to confirm the selection.
Min duration
Default setting of the minimum operating time that the customer
can select during configuration of the quick-start button or from
the menu during heating/ventilation. The value for "Min duration"
can be set between 10 minutes and the "Max duration".
3
Select the "Service" symbol in the main menu.
3
The "Quick-start" symbol appears on the display.
Turn the control knob to select the desired symbol "Min dura-
tion".
Press the control knob to confirm the selection.
3
The "Min duration" appears on the display and the "hour" digit
flashes.
Turn the control knob to select the desired "hours" for the "Min
duration".
Press the control knob to confirm the selection.
3
The "Min duration" appears on the display and the "minute"
digit flashes.
Turn the control knob to select the desired "minutes" for the
"Min duration".
Press the control knob to confirm the selection.
Max duration
Default setting of the maximum operating time that the customer
can select during configuration of the quick-start button or from
the menu during heating/ventilation. The value for "Max duration"
can be set between the value for "Min duration" and the maxi-
mum time permissible for the selected heater.
3
Select the "Service" symbol in the main menu.
3
The "Quick-start" symbol appears on the display.
Turn the control knob to select the desired symbol "Max dura-
tion".
Press the control knob to confirm the selection.
3
The "Max duration" appears on the display and the "hour" digit
flashes.
Turn the control knob to select the desired "hours" for the "Max
duration".
Press the control knob to confirm the selection.
3
The "Max duration" appears on the display and the "minute"
digit flashes.
Turn the control knob to select the desired "minutes" for the
"Max duration".
Press the control knob to confirm the selection.
Permanent mode
This allows continuous operation of the heater to be enabled or
barred for the user. Permanent mode is only possible with heaters
which support this mode. If this option is selected for heaters
which do not support permanent mode, the heater dictates the
operating time when the user starts the heating/ventilation func-
tion in permanent mode.
3
Select the "Service" symbol in the main menu.
3
The "Quick-start" symbol appears on the display.
Turn the control knob to select the desired symbol "Permanent
mode".
Press the control knob to switch between "On" and "Off".
This setting is saved without confirmation.