EasyManuals Logo

Winterhalter PT-M User Manual

Winterhalter PT-M
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Commissioning | 5 | English
Operating instructions PT Series | 89014547; 2021-03 | 33
Other configuration options
Setting Application for... Set the dosing amount
Peristaltic pump Winterhalter dosing device with an output of
166 ml/min (e.g. SP166Z)
On the warewasher’s display. Set poten-
tiometer to max.
Fluidos integral Fluidos type dosing device On the warewasher’s display.
MPI / PPX integral MPI type dosing device On the warewasher’s display.
MPI / PPX external PPX type dosing device On the warewasher’s display. Observe the dos-
ing device commissioning instructions.
5.7 Configuring the transfer strip
The service technician requires this menu when he connects an external dosing device to the warewasher.
1 2
Item Name
1 Settings for the detergent dosing device
2 Settings for the rinse aid dosing device
Setting the detergent dosing device
32
1
Item Name
1 Reset to default setting
2
Configuration options }32
3 Save settings
Setting the rinse aid dosing device
321
Item Name
1 Reset to default setting
2
Configuration options }32
3 Save settings

Table of Contents

Other manuals for Winterhalter PT-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Winterhalter PT-M and is the answer not in the manual?

Winterhalter PT-M Specifications

General IconGeneral
Rack size500 x 500 mm
Water consumption per cycle2.4 liters
Total connected load9.5 kW
Protection classIPX5
Power supply400 V / 50 Hz / 3~

Related product manuals