8
INSTALLATION & COMMISSIONING
8 716 115 752 (2009/07)
4.2 PRE-COMMISSIONED TRANSMITTER & RECEIVER LOCATION
The MT10RF Mechanical Thermostat and
Receiver are pre commissioned (paired) at the
factory.
B Fit and connect the Receiver in the boiler
control panel, see page 7.
B Locate a flat bladed screwdriver into the slots
in the base plate [B] as shown, twist to
release the Transmitter [A] from the base
plate [B].
Fig. 7 Removing the transmitter
B Switch on the electrical power to the boiler.
B Fit the batteries correctly into the battery
compartment [F] of the Transmitter [A].
The Transmitter and Receiver will
communicate immediately.
The boiler‘s receiver LED will briefly flash
twice when a signal is received.
Fig. 8 Fitting the batteries
FUNCTIONAL CHECK
B Move the manual switch on the Transmitter to
the constant comfort position.
B Rotate the Comfort temperature dial to 30 °C.
B If the room temperature is less than 30 °C,
then within 10 to 30 seconds of making
adjustments detailed above, the LED on the
receiver will briefly flash twice while detecting
the transmitter signal and then remain on.
The boiler will fire.
B If the operation is successful, rotate the
comfort dial to your desired room
temperature.
B Move the manual switch on the Transmitter to
the Automatic position.
B Programme the Transmitter to the end user‘s
requirements, see page 12.
If the operation is not successful, follow the
Transmitter radio link set up on page 10.
Fig. 9 Functional checks
Low Battery
Comfort
Economy
A
B
8716115752-11.1 Wo
A
F
8716115752-12.1 Wo
8716115752-13.1 Wo