Operation
2–18 975-0170-01-01
In Safe mode, the RS3000 continues to communicate, but the inverting
and charging functions are disabled.
When to use Use Safe mode when you are adding or removing devices from the
network. Authorized service personnel must also put the System Control
Panel in Safe mode before performing software upgrades and diagnostics
with the Xantrex Diagnostic Tool.
If the System Control Panel is powered off while in Safe mode, it will be
in Safe mode when it is powered up again.
To return to Operating mode:
On the System Settings menu, under Desired Mode, select
“Operating.”
Putting the System into Safe Mode
When you are installing or removing devices from the Xanbus system,
putting the system into Safe mode prevents unexpected behavior.
To enter Safe mode:
1. On the Select Device menu, use the down arrow button to highlight
System.
The cursor on the right of the screen indicates where you are in the
menu.
2. Press Enter.
The System Settings menu appears.
Figure 2-6
Select Device Menu

Table of Contents

Other manuals for Xantrex RS3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex RS3000 and is the answer not in the manual?

Xantrex RS3000 Specifications

General IconGeneral
BrandXantrex
ModelRS3000
CategoryInverter
LanguageEnglish

Related product manuals