DP-7022P Users Manual
9
Display method:
Set parameters status PX.XX: the first X represents group number, the latter
two X represent parameter number in this group;
Monitor status UXX: XX represent monitor parameter number;
Auxiliary function status FX.XX: the first X represents group number, the
latter two X represent parameter number in this group;
Alarm status EXX: XX represents alarm number.
Run status:
Driver is closed
Driver is in enabled OFF status (panel force
enable OFF)
Running
Driver is in enabled ON status
4-2Parameter setting
We can select and adjust function by setting parameter. Table 1 is the parameter
information.
Modbus address: 0x0000x005
Table 1 Driver parameters
P0
Name
Unit
Factory
value
Range
Note
P0.00
Set phase
current(effective value)
0.1A
10
070
P0.01
Half current enable
0
01
0: half current 1 full current
P0.02
Pulse quantity per cycle
16
2655
Actual value= set value×100
P0.03
Modbus number
1
1255
P0.04
Serial port parameters
2206
02209
See table 2
P0.05
Select built-in/out pulse
0
01
0: outside pulse
1: built-in pulse
Auxiliary function status
Monitor status
Parameter status
Run status