FT2DR/DE Technical Supplement
Alignment
ALIGNMENT-9
B-Band 430 MHz Band Adjustment
NOTICE: Do not touch the following Alignment
Menus in B-Band 430 MHz Band Adjustment:
"PLL REF "
"HI POWER"
"L3 POWER"
"L2 POWER"
"L1 POWER"
"MAX DEV"
"TONE DEV"
"DCS DEV"
Press the
[
A/B
]
key to change the operating band
to the "B-Band".
Press the
[
BAND
]
key to select the 430 MHz Ama-
teur band.
Note: When the transceiver recalls Alignment Menu
"PLL REF", the
[
A/B
]
and
[
BAND
]
key operation is
ignored. In this case, rotate the
DIAL
knob to select an
Alignment Menu other than "PLL REF".
Receiver Sensitivity Adjustment (TUNE DEV)
Connect the test equipment as shown in Figure 2:
RX Alignment Setup.
Rotate the
DIAL
knob to select the Alignment
Menu "TUNE DEV".
Set the RF Signal Generator output to 435.100
MHz, at a level of -10 dBμ, ±3.5 kHz deviation
with a 1 kHz audio tone.
Press the
[
V/M
]
button (the "Data" will appear
on the display).
Rotate the
DIAL
knob for maximum deection
on the SINAD meter.
Press the
[
V/M
]
button (the "Data" will disap-
pear on the display).
Squelch Hysteresis Conrmation (HIS SQL)
Rotate the
DIAL
knob to select the Alignment
Menu "HIS SQL".
Conrm that the alignment value is "0".
Squelch Threshold Adjustment (THLD SQL)
Connect the test equipment as shown in Figure 2:
RX Alignment Setup.
Rotate the
DIAL
knob to select the Alignment
Menu "THLD SQL".
Set the RF Signal Generator output to 435.100
MHz, at a level of -11 dBμ, ±3.5 kHz deviation
with a 1 kHz audio tone.
Press the
[
V/M
]
button (the "Data" will appear
on the display).
Press the
[
X
]
key two times to store the Squelch
Threshold level.
Press the
[
V/M
]
button (the "Data" will disap-
pear on the display).
Tight Squelch Adjustment (TIGH SQL)
Connect the test equipment as shown in Figure 2:
RX Alignment Setup.
Rotate the
DIAL
knob to select the Alignment
Menu "TIGH SQL".
Set the RF Signal Generator output to 435.100
MHz, at a level of -4 dBμ, ±3.5 kHz deviation
with a 1 kHz audio tone.
Press the
[
V/M
]
button (the "Data" will appear
on the display).
Press the
[
X
]
key two times to store the Squelch
Tight level.
Press the
[
V/M
]
button (the "Data" will disap-
pear on the display).
FM S-Meter S-1 Adjustment (S1 LEVEL)
Connect the test equipment as shown in Figure 2:
RX Alignment Setup.
Rotate the
DIAL
knob to select the Alignment
Menu "S1 LEVEL".
Set the RF Signal Generator output to 435.100
MHz, at a level of -7 dBμ, ±3.5 kHz deviation
with a 1 kHz audio tone.
Press the
[
V/M
]
button (the "Data" will appear
on the display).
Press the
[
X
]
key two times to store the FM
S-Meter S-1 level.
Press the
[
V/M
]
button (the "Data" will disap-
pear on the display).