127878-YIM-C-1208
Johnson Controls Unitary Products 23
TABLE 10: ELECTRICAL DATA - DR120 W/O PWRD CONVENIENCE OUTLET
TABLE 11: ELECTRICAL DATA - DR120 W/PWRD CONVENIENCE OUTLET
RL
LR
FL
23 2 3 2 3232 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 13.5 37.5 57.1 60.5 64.0 67.3 60 70 70 70
2TP04522425 18 50.0 72.7 76.1 79.6 83.0 80 80 80 90
2TP04523625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110
2TP04525425 40.6 112.7 151.1 154.5 158.0 161.4 175 175 175 175
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 18 43.3 64.4 67.8 71.3 74.6 70 70 80 80
2TP04522425 24 57.7 82.4 85.8 89.3 92.7 90 90 90 100
2TP04523625 34 81.8 112.5 115.9 119.4 122.7 125 125 125 125
2TP04525425 54 129.9 140.2 143.5 147.0 150.4 150 175 175 175
None -- -- 26 27.2 28.2 29.4 30 35 35 35
2TP04521846 18 22.6 32.2 33.7 34.9 36.4 35 35 35 40
2TP04522446 24 30.1 41.2 42.7 44 45.5 45 45 45 50
2TP04523646 34 42.7 56.2 57.7 59 60.5 60 60 60 70
2TP04525446 54 67.8 70.1 71.6 72.8 74.3 80 80 80 80
None -- -- 20.6 21.1 22.4 22.9 25 25 25 25
2TP04521858 18 18.1 26.2 26.8 28.4 29 30 30 30 30
2TP04522458 24 24.1 33.4 34 35.6 36.2 35 35 40 40
2TP04523658 34 34.1 45.4 46 47.6 48.3 50 50 50 50
2TP04525458 54 54.2 56.5 57.1 58.7 59.3 70 70 70 70
*
Voltage
Compressors
OD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse Size
w/Power
Exhaust
(Amps)
FLA FLA
208
16.0 137.0 3.5 8.2 10.9 5.5 0.0
230
16.0 137.0 3.5 8.2 10.9 5.5 0.0
460
8.3 69.0 1.6 4.1 5.3 2.2 0.0
575
6.4 58.0 1.3 3.6 4.1 1.8 0.0
Maximum HACR breaker of the same AMP size is applicable.
RL
LR
FL
23 2 3 2 3232 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 13.5 37.5 69.6 73.0 76.5 79.8 70 80 80 80
2TP04522425 18 50.0 85.2 88.6 92.1 95.5 90 90 100 100
2TP04523625 25.5 70.8 111.2 114.6 118.1 121.5 125 125 125 125
2TP04525425 40.6 112.7 163.6 167.0 170.5 173.9 175 175 175 175
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 18 43.3 76.9 80.3 83.8 87.1 80 90 90 90
2TP04522425 24 57.7 94.9 98.3 101.8 105.2 100 100 110 110
2TP04523625 34 81.8 125.0 128.4 131.9 135.2 125 150 150 150
2TP04525425 54 129.9 152.7 156.0 159.5 162.9 175 175 175 175
None -- -- 31 32.2 33.2 34.4 35 40 40 40
2TP04521846 18 22.6 38.4 39.9 41.2 42.7 40 40 45 45
2TP04522446 24 30.1 47.5 49 50.2 51.7 50 50 60 60
2TP04523646 34 42.7 62.5 64 65.2 66.7 70 70 70 70
2TP04525446 54 67.8 76.3 77.8 79.1 80.6 90 90 90 90
None -- -- 24.6 25.1 26.4 26.9 30 30 30 30
2TP04521858 18 18.1 31.2 31.8 33.4 34 35 35 35 35
2TP04522458 24 24.1 38.4 39 40.6 41.2 40 40 45 45
2TP04523658 34 34.1 50.4 51 52.6 53.3 60 60 60 60
2TP04525458 54 54.2 61.5 62.1 63.7 64.3 70 70 70 70
*
Voltage
Compressors
OD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse Size
w/Power
Exhaust
(Amps)
FLA FLA
208
16.0 137.0 3.5 8.2 10.9 5.5 10.0
230
16.0 137.0 3.5 8.2 10.9 5.5 10.0
5.0
460
8.3 69.0 1.6
1.3
4.1 5.3 2.2
Maximum HACR breaker of the same AMP size is applicable.
3.6 4.1 1.8 4.0
575
6.4 58.0